Keeping tradition with doing things backwards, I’ve finally got a UPS for the rack (mounted in the bottom of the stack). Got a PowerWalker VI 2200R. Its a 2U unit which is all the space I’ve got left in the rack. Decent price and decent I/O with USB, serial and a slot-in for network expansion + 4 IEC outputs. Its powering everything in the rack and connected via USB to my main server which runs a NUT server that other machines can connect to. A calibration run (100-80%) puts the runtime at about 20 min. Long enough that I’m comfortable setting things to shut down when 20% capacity remains. Summary, I sleep better now.

The rack with the UPS at the bottom

NUT output

  • nezbyte@lemmy.world
    link
    fedilink
    English
    arrow-up
    0
    ·
    8 months ago

    Great setup! I’ve heard that it is best practice to keep a little distance between servers/drives and the UPS just to be safe from vibrations or EMI. Does anyone know if this is still something to worry about?

    • glimse@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      8 months ago

      Back when I built racks, our “standard” was UPS at the bottom, all drives at the top…but mainly for accessibility. Hadn’t even thought about vibrations or interference!

      • catloaf@lemm.ee
        link
        fedilink
        English
        arrow-up
        0
        arrow-down
        1
        ·
        8 months ago

        Drives at the top? Hell no. SANs are heavy, they go in the bottom half too (assuming a mixed rack). Especially if you have those disk shelves that slide out so they hold 3.5" drives three deep. Top of the rack is for network hardware and such.